Voltron 220KV Oil-Immersed Power Transformers Supplier

Brand: Voltron Type: Oil-Immersed Phase: Three Phase Rated Capacity: 31500kVA-420000kVA Vector Group: YNa0d11, YNyn0d11, YNd11 High Voltage: 220KV-242KV Low Voltage: 6.3KV-38.5KV Nature of Business: Manufacturer

1. Flexible design to meet the needs of different users

First-class product quality in ChinaThe first-class R & D team in the industry ensures that the performance indicators of products meet or exceed the national standards, introduces scientific management mode, and standardizes the operation of each process to ensure the excellent quality of each product.

Flexible design to meet the needs of different users. According to the actual needs of customers, the product structure can be designed. signed flexibly, and all kinds of accessories can be selected according to users’ requirements, to meet the personalized needs of different customers.

2. Safe, no partial discharge, high efficiency, and energy-saving

1) Seven-stage temperature control technology

2) Low loss: adopt a special design scheme, the no-load loss is 20% lower than the national standard, and the load loss is 5% lower than the national standard.

3) Low noise: the noise is 3-5 dB lower than the national standard

4) No partial discharge: factory test is less than 40pc

5) Anti-short circuit: pass the sudden short circuit test of the national transformer testing center.

Scope of application: widely used in large and medium-sized city power grids large thermal power plants, and industrial and mining enterprises.

3. DuPont Nomex Insulation System

1) World-recognized high-quality electrical insulating materialsChemical – there is no weak C-H bond, with good chemical stability.

2) Heat resistance: long-term stable operation at 220 ℃; Short-term operation at 350 ℃; At 250 ℃, it will not melt, flow or support combustion; No toxic or corrosive gas will be released

at 750 ℃.

3) Safety, and environmental protection – no toxic reaction to people and animals; the smoke concentration is low and no harmful gas is produced during burning.

S20-220KV 31500KVA-420000KVA Three Phase Double Winding Non-Excitation Voltage Regulating Power Transformer

Rated Capacity (KVA)

Voltage Combination and Tapping Range

Vector Group

No Load Loss (KW)

Load Loss (KW)

No Load Current (%)

Impedance (%)

HV (KV)

LV (KV)

31500

220±2×2.5%

242±2×2.5%

6.3
6.6
10.5

YNd11

18

115

0.56

12-14

40000

21

134

0.56

50000

25

161

0.52

63000

30

188

0.52

75000

10.5
13.8

34

213

0.48

90000

40

246

0.44

120000

49

304

0.44

150000

10.5
13.8
15.75
18
20

58

360

0.4

160000

60

378

0.39

180000

66

413

0.36

240000

83

484

0.33

300000

15.75
18
20

98

577

0.3

360000

112

662

0.3

370000

114

675

0.3

400000

122

716

0.28

420000

125

742

0.28

Note:
1. Transformers with a rated capacity less than 31500kVA and other voltage combinations can also be provided according to requirements.
2. transformer with low voltage of 35kV can also be provided according to requirements.
3. The non tapping structure is preferred, and taps can be set if required.
4. When the annual average load rate of transformer is between 45% and 50%,the highest operation eficiency can be obtained byusing the loss value in the table.
SS22-220KV 31500KVA-300000KVA Three Phase Three Winding Non-Excitation Voltage Regulating Power Transformer
Rated Capacity (KVA)
Voltage Combination and Tapping Range
Vector Group
No Load Loss (KW)
Load Loss (KW)
No Load Current (%)
Impedance (%)
HV (KV)
MV (KV)
LV(KV)
Step Up
Step Down
31500
220±x2.5%
230±2×2.5%
242±2×2.5%
69
115
121
6.3
6.6
10.5
21
36
37
38.5
YNyn0d11
18
138
0.48
HV-MV
22-24
HV-LV
12-14
MV-LV
7-9
HV-MV
12-14
MV-LV
22-24
MV-LV
7-9
40000
21
165
0.42
50000
24
194
0.36
63000
29
231
0.38
90000
10.5
13.8
21
36
36
37
38.5
37
300
0.33
120000
46
369
0.33
150000
10.5
13.8
15.75
21
36
37
38.5
55
438
0.28
180000
62
500
0.28
240000
72
616
0.22
300000
91
726
0.2
Note:
1. The capacity distribution ofthe load in the table is (100 / 100 / 100)%; The capacity distribution of boost structure can be (100 / 50/ 100)%; The capacity allocation of Buck structure can be (100 /100/50)% or (100/50 /100)%
2. Transformers with rated capacity less than 31500kv, A and other voltage combinations can also be provided according to requirements,
3. The transformer with low voltage of 35kV can also be provided;
4. The non tapping structure is prefered, and taps can be set if required;
5. When the annual average load rate of transformer is about 45%, the highest operation efficiency can be obtained by using the loss value in the table.

SSZ20-220KV 31500KVA-240000KVA Three Phase Three Winding OLTC Power Transformer

Rated Capacity (KVA)

Voltage Combination and Tapping Range

Vector Group

No Load Loss (KW)

Load Loss (KW)

No Load Current (%)

Capacity Allocation (%)

Impedance (%)

HV (KV)

MV (KV)

LV(KV)

31500

220±8×1.25%

230±8×1.25%

69
115
121

6.3
6.6
10.5
21
36
37
38.5

YNyn0d11

23

138

0.63

100/100/100
100/50/100
100/100/50

HV-MV
12-14
HV-LV
22-24
MV-LV
7-9

40000

27

165

0.60

50000

31

194

0.60

63000

36

231

0.55

90000

10.5
21
36
37
38.5

47

300

0.44

120000

60

369

0.44

150000

70

438

0.39

180000

81

538

0.39

240000

100

667

0.35

Note:
1. The data listed in the table are applicable to step-down structure products, and step-up structure products can also be provided as required;
2. A transformer with 35kV low voltage can also be provided according to requirements;
3. When the annual load rate of the transformer is between 45% and 50%,the highest operation efficiency can be obtained by using the loss value in the table.

S11-220KV 3150KVA-240000KVA Three Phase winding non-excitation voltage regulating autotransformer

Rated Capacity (KVA)

Voltage Combination and Tapping Range

Vector Group

Step Up Combination

Step Down Combination

Impedance (%)

HV (KV)

MV (KV)

LV(KV)

No Load Loss (KW)

Load Loss (KW)

No Load Current (%)

No Load Loss (KW)

Load Loss (KW)

No Load Current (%)

Step Up

Step Down

31500

220±2×2.5%
230±2×2.5%
242±2×2.5%

115
121

6.6
10.5
21
36
37
38.5

YNa0d11

20

111

0.45

17

94

0.4

HV-MV
12-14
HV-LV
8-12
MV-LV
14-18

HV-MV
8-10
HV-LV
28-34
MV-LV
18-24

40000

23

136

0.45

20

114

0.4

50000

27

161

0.4

24

136

0.34

63000

32

190

0.4

28

162

0.34

90000

40

262

0.34

36

222

0.28

120000

10.5
13.8
15.75
18
21
36
37
38.5

49

323

0.34

44

273

0.28

150000

58

384

0.28

52

324

0.26

180000

67

439

0.28

60

367

0.26

240000

79

545

0.16

71

478

0.2

Note:
1. The capacity allocation of the step-up structure is (100 / 50 / 100)9%, and that of step-down structure is (100 / 100 / 50)%,
2. The short circuit impedance in the table is 100% of the rated capacity;
3. Transformer with low voltage of 35kV can also be provided on request,
4. The non-tapping structure is preferred, and taps can be set if required;
5. When the annual load rate of the transformer is about 40%,the highest operation eficiency can be obtained by using the loss value in
the table.

SSZ20-220KV 31500KVA-300000KVA Three Phase Three Winding Non Excitation Voltage Regulating Power Transformer

Rated Capacity (KVA)

Voltage Combination and Tapping Range

Vector Group

No Load Loss (KW)

Load Loss (KW)

No Load Current (%)

Impedance (%)

HV (KV)

MV (KV)

LV(KV)

Step Up

Step Down

31500

220±2×2.5%
230±2×2.5%
242±2×2.5%

69
115
121

6.3
6.6
10.5
21
36
37
38.5

YNyn0d11

21

138

0.56

HV-MV
22-24
HV-LV
12-14
MV-LV
7-9

HV-MV
12-14
MV-LV
22-24
MV-LV
7-9

40000

25

165

0.5

50000

29

194

0.44

63000

34

231

0.44

90000

10.5
13.8
21
36
37
38.5

44

300

0.39

120000

55

369

0.39

150000

10.5
13.8
15.75
21
36
37
38.5

65

438

0.33

180000

73

500

0.33

240000

91

616

0.28

300000

108

726

0.24

Note:
1. the capacity distribution of the load in the table is (100/100/100)%; The capacity distribution of the step up structure can be(100/50/100)%; The capacity distribution of the step-down structure can be (100/100/50)%, or (100/50/100).
2. transformers with rated capacity less than 31500kva and other voltage combinations can also be provided as reguired.
3. transformers with low voltage of 35kV can also be provided.
4. the non-tap structure is preferred, lf required by operation, tap can be set.
5. when the average load rate of the transformer is about 45%, the maximum operating efficiency can be obtained by using the loss value
in the table.

Voltron Transformer is a professional transformer manufacturer! Our production base covers an area of more than 600 acres (40 hectares) with extensive facilities and a total construction area of 180,000 square meters. We have a professional team of more than 1,000 employees. We have advanced transformer production and testing equipment here to ensure that we provide customers with high-quality power transformer products.

We boast an array of cutting-edge equipment representing a high standard within the industry, including a complete set of shearing machines, fully automated winding machines, robot-operated stacking machines, the Hedrch Vacuum Casting Equipment, vacuum impregnation systems, air cushion transport vehicles, a fully enclosed production workshop with a cleanliness level of 100,000, 20-ton vertical winding machines, 10-ton horizontal winding machines, coal-oil gas phase drying equipment, and a 200-ton overhead crane. We adopt the latest technology and processes to ensure our products comply with international standards and customer needs.

We have a strong production capacity of 30 million kVA power transformers annually. This means we can cater to all sizes and types of power transformer needs, from small applications to large energy projects. No matter what specifications our customers require, we deliver them on time and support them with high quality and reliability.